Power Supply Comparisons
Difference Between Linear and Switching Power Supply
Switching
Regulated Power Supplies |
Linear
Regulated Power Supplies |
Unregulated Power Supplies |
|
Circuit Design | complex | moderately complex | simple |
Part
Count |
high | medium | low |
Load
Regulation |
0.05% to 0.5% | .005% to 0.2% | +10% (1/2
load to No Load (NL)) -10% (1/2 load to Full Load (FL)) |
Line Regulation | 0.05% to 0.2% | 0.005% to 0.05% | directly
proportional to AC input change |
Ripple (RMS) | 10 mv to 25 mv | 0.25 mv to 1.5 mv | 0.5 v to 5 v |
Transient
Recovery |
300
microseconds (1/2L to FL) |
50-100
microseconds (NL to FL) |
N/A |
Efficiency | 70-85% | 40-60% | 90-95% |
Hold-up Time | 15-30 milliseconds | 1-2 milliseconds | |
EMI | high | very low | very low |
Leakage | high | low | very low |
Size (power density) |
small
size (high power density) |
large
size (low power density) |
medium
size (medium power density) |
Weight (Power to Weight Ratio) |
light (high) |
heaviest (low) |
heavy (low) |
Power Factor | 0.6
- 0.7 without PFC >0.95 with PFC |
0.6 - 0.7 | 0.6 - 0.7 |
Cooling | convection or fan | convection or fan | convection |
Isolation | yes | yes | yes |
Input
Voltage Range |
90
- 132 VAC (without PFC) and/or 180 - 264 VAC (without PFC) ----------------- 90 - 264 VAC (with PFC) |
105
- 125 VAC and/or 210 - 250 VAC |
0
- 125 VAC 0 - 250 VAC Output directly proportional to input |