None
B1
IEC inlet on the rear, with accessible fuse. (Not available with: B4, B6, K5, L2, case size LM6A)
B2
IEC inlet on the front, with accessible fuse. (Not available with: B5, B6, C8, E6, K5, L2)
None
B3
210-250 VAC input. Internally fused for a single phase source. $15.00
B4
105-125 VAC or 210-250 VAC input, selectable with switch on rear. Internally fused for a single phase source. (Not available with: B1, B5, B9, K5, case size LM6A) $25.00
B5
105-125 VAC or 210-250 VAC input, selectable with switch on front. Internally fused for a single phase source. (Not available with: B2, B4, B8, C8, E6) $25.00
B6
105-125 VAC or 210-250 VAC strappable input. External fusing required. Input voltage of 115 or 230 VAC can be selected by the use of jumpers on a 4 place pluggable terminal block located on the front panel. (Not available with: B1, B2, B3, B8, C8, E6, K5) $20.00
L1
90-110 VAC input. Internally fused for a single phase source. (Add 5 days to standard shipping time.) (Not available with: C8, E5) $40.00
L2
22-26 VAC input. Internally fused for a single phase source. (Add 5 days to standard shipping time.) (Not available with: B1, B2, B8, B9, C8, E6, K7, E5) $40.00
L3
195-220 VAC input. Internally fused for a single phase source. (Add 5 days to standard shipping time.) (Not available with: C8, E6, E5) $40.00
(standard:screwdriver slot accessible through the front panel for Vout adjust.)
(voltage and/or current) Voltage mode accuracy: 0.5%. Current mode accuracy is 0.5% or +/- 15mA, whichever is greater. Accuracy percentages do not apply below 5% of output rating.
For models with no programming or with 0-10v programming (option “C6”) Voltage Monitor Terminal: Permits remote monitoring of output voltage, stepped down by a ratio of 10:1 (for 3.3v to 90v models) or 100:1 (for 100v to 150v models). Accuracy is 0.5% of maximum rated output voltage.Current Monitor Terminal: For models with greater than 10 amps output current: permits remote monitoring of output current, stepped down by a ratio of 100 mV/Amp (accuracy is 1% of maximum rated output current). For models with less than 10 amps output current: permits remote monitoring of output current, stepped down by a ratio of 1000 mV/Amp (Accuracy is 1% of maximum rated output current or +/- 15mV, whichever is greater).For models with 0-5v programming (option “C5”) Voltage Monitor Terminal: Permits remote monitoring of output voltage, stepped down by a ratio of 10:1 (for 3.3v to 45v models) or 100:1 (for 48v to 150v models). Accuracy is 0.5% of maximum rated output voltage. Current Monitor Terminal: For models with greater than 45 amps output current: permits remote monitoring of output current, stepped down by a ratio of 10 mV/Amp. For models with from 5 amps to 45 amps output current: permits remote monitoring of output current, stepped down by a ratio of 100 mV/Amp. For models with less than 4.5 amps output current: permits remote monitoring of output current, stepped down by a ratio of 1000 mV/Amp. (Accuracy is 1% of maximum rated output current or +/- 15mV, whichever is greater).(When monitoring the output voltage and/or current by means of the monitor terminals, the use of an instrument having an input impedance of at least 10 megohms is recommended.)
None
E5
May be floated at 1000 Vdc above case. (Available with: Single Output models, B1, B2, B3, B4, B5, B6, B7, B8, B9, D1, D2, F1, K6)
<1% initial Accuracy, ±0.5% Line and ±0.5% Load Regulation, <10mv peak-to-peak ripple. (Not available with option G5.)
None
H1
Auxiliary output: 3.3 Vdc, 0.1 amp (Not available with: G5, E5)
H2
Auxiliary output: 5 Vdc, 0.1 amp (Not available with: G5, E5)
H3
Auxiliary output: 12 Vdc, 0.1 amp (Not available with: G5, E5)
H4
Auxiliary output: 13.8 Vdc, 0.1 amp (Not available with: G5, E5)
H5
Auxiliary output: 15 Vdc, 0.1 amp (Not available with: G5, E5)
H6
Auxiliary output: -5 Vdc, 0.1 amp (Not available with: G5, E5)
H7
Auxiliary output: -12 Vdc, 0.1 amp (Not available with: G5, E5)
H8
Auxiliary output: -15 Vdc, 0.1 amp (Not available with: G5, E5)
*The “$35(one-time only charge)” is only added to the total cost of the power supply one time no matter how many options are ordered.
GB8 (View drawing of Mounting Kit for Wall Mounting ) To mount from the power supply side of the mounting surface, necessary when the other side of the mounting surface is inaccessible. This kit consist of four aluminum brackets and four machine screws for fastening them to the power supply, effectively adding mounting flanges to the power supply.
GBR (View drawing of Mounting Kit for Wall Mounting ) To mount from the power supply side of the mounting surface, necessary when the other side of the mounting surface is inaccessible, use accessory Mounting Kit GBR. Required only when end mounting with limited space above and below the supply, this kit consists of four aluminum brackets and uses the existing rear cover screws for fastening them to the power supply.
LH35DIN (View drawing of Mounting Kit for DIN Rail Mounting (Horizontal mounting) ) Horizontal mounting
LR35DIN (View drawing of Mounting Kit for DIN Rail Mounting (Rear mounting) ) Rear mounting
LV35DIN (View drawing of Mounting Kit for DIN Rail Mounting (Vertical mounting) ) Vertical mounting
Model Number with Selected Options
Subtotal(Not including accessories)
L36MC140
$410
BACK