We manufacture millions of power supply models, but if you can't find what you need in our standard models, we can fill your needs with one of our custom power supplies or custom power systems using the System Builder.
Infinity Rack Mounting & Benchtop Linear Regulated (to 1200 watts)
AC-DC wide adjust output
OPTIONS
Overvoltage Protection
$110.00
A1
OVP set 15% above maximum rated output. Non-latching. (Single Output models only. Not available with option C9.)
A2
OVP set 15% above rated output. Latching. Reset by momentarily removing AC input power.
AC Input Voltage Options
B3
210-250 VAC input. Internally fused for a single phase source.
$15.00
B4
105-125 VAC or 210-250 VAC input, selectable with switch on rear. (Available with 2U13/2B13 case size models only.)
$25.00
B6
105-125 VAC or 210-250 VAC strappable input. Input voltage of 115 or 230 VAC can be selected by the use of jumpers on a 4 place pluggable terminal block located on the rear panel. (Available with 3U17/3B17 & 4U17/4B17 case size models only. Circuit breakers and AC line filters included.)
$300.00
L1
90-110 VAC input. Internally fused for a single phase source. (Add 5 days to standard shipping time.)
$40.00
L3
195-220 VAC input. Internally fused for a single phase source. (Add 5 days to standard shipping time.)
$40.00
Voltage Output Adjust and Current Limit Adjust Options
C1
Front panel knobs; (one voltage, one current) used to adjust output voltage and current. (Current adjustment range is from zero to maximum rated output current.)
$85.00
C2
Current Limit adjustment screwdriver slot accessible through the rear panel. (Current adjustment range is from zero to maximum rated output current.)
$10.00
S1
Front panel shaft locks. Provides screwdriver slot adjustment with shaft locks exerting an even frictional drag over the control shafts, resisting accidental rotation.
$85.00
Inhibit or Enable Options
$10.00
C3
Inhibit control, TTL compatible. To disable the supply, apply a voltage between the "Rtn" terminal and the "Inh/Ena" terminal.The voltage can be any value from +3 Vdc to +15 Vdc.
C4
Enable Control, TTL compatible. To enable the DC output, the "Inh/Ena" terminal must either be shorted to the "Rtn" terminal or pulled to within 0.8 Vdc of the "Rtn" terminal. An open collector or contact closure can be used.
The output voltage and current may be programmed from 0 to full rating by means of control voltage inputs of 0 to +5 Vdc.
C6
The output voltage and current may be programmed from 0 to full rating by means of control voltage inputs of 0 to +10 Vdc. Voltage mode accuracy: 0.5%. Current mode accuracy: 0.5% or ±15 mA, whichever is greater. Accuracy percentages do not apply below 5% of output rating.
Voltage and Current Monitoring (Included with option M3)
$15.00
C7
For models with no programming or with 0-10v programming (option “C6”):
Voltage Monitor Terminal: Permits remote monitoring of output voltage, stepped down by a ratio of 10:1 (for 3.3v to 90v models) or 100:1 (for 100v to 150v models). Accuracy is 0.5% of maximum rated output voltage. Current Monitor Terminal: For models with greater than 10 amps output current: permits remote monitoring of output current, stepped down by a ratio of 100 mV/Amp (accuracy is 1% of maximum rated output current). For models with less than 10 amps output current: permits remote monitoring of output current, stepped down by a ratio of 1000 mV/Amp.
(Accuracy is 1% of maximum rated output current or ±15 mA, whichever is greater.)
For models with 0-5v programming (option “C5”):
Voltage Monitor Terminal: Permits remote monitoring of output voltage, stepped down by a ratio of 10:1 (for 3.3v to 45v models) or 100:1 (for 48v to 150v models). Accuracy is 0.5% of maximum rated output voltage. Current Monitor Terminal: For models with greater than 45 amps output current: permits remote monitoring of output current, stepped down by a ratio of 10 mV/Amp. For models with from 5 amps to 45 amps output current: permits remote monitoring of output current, stepped down by a ratio of 100 mV/Amp. For models with less than 4.5 amps output current: permits remote monitoring of output current, stepped down by a ratio of 1000 mV/Amp. (Accuracy is 1% of maximum rated output current or ±15 mA, whichever is greater.)
(When monitoring the output voltage and/or current by means of the monitor terminals, the use of an instrument having an input impedance of at least 10 megohms is recommended.)
Latching Overcurrent control
$15.00
C9
If current is greater than 15% of the maximum rated output current, the power supply latches off. Reset by momentarily removing AC input power. This option is included with Option A2. (Available on Single Output models only. Not available with option A1.)
Ethernet/USB/RS232 Digital Interface
$350.00
DIO1
Can be used to monitor and/or control output voltage and current. Includes isolated Ethernet (10/100Mbps), RS232, and USB (RS485 option DIO2 available) interfaces, utilizing 16 bit DAC and ADC. This option incorporates C4 (Enable), C6 (Output Programming), and C7 (Voltage/Current Monitoring) options.
Ethernet/USB/RS232/RS485 Digital Interface
$375.00
DIO2
Can be used to monitor and/or control output voltage and current. Includes isolated Ethernet (10/100Mbps), RS232, RS485, and USB interfaces, utilizing 16 bit DAC and ADC. This option incorporates C4 (Enable), C6 (Output Programming), and C7 (Voltage/Current Monitoring) options.
Output blocking protection diode
$45.00
E1
Used for battery charging or redundant applications. Derate output by 10%.
Transient protection for electrically noisy environments
$55.00
E2
Transient protection for AC input and DC output.
High Frequency pulsed load filtering
$30.00
E3
Recommended for applications such as "switched loads" and "stepper motors".
Series Operation Diode
$45.00
E4
Allows power supplies to operate in series, for applications requiring higher output voltage.
Alarm with Relay Contacts Options
$15.00
G1
NC Relay contacts close when output voltage drops more than 10% below nominal.
G2
NO Relay contacts open when output voltage drops more than 10% below nominal.
Front Panel Mounted LED Output Indicator
$20.00
G3
Green Indicates DC is on
Temperature monitor
$25.00
G5
The temperature monitor is used to measure the power supply’s internal temperature. Monitor output voltage is set to 2.5 Vdc at 25°C and varies above or below this value by 0.1 Vdc per °C. For example, if the temperature is 20°C the output will be 2 Vdc. (Not available with options H1-H8).
Handles
$45.00
H
Handles
Additional Low Current Auxiliary Voltage Options
$25.00
H1
Auxiliary output: 3.3 Vdc, 0.1 amp
H2
Auxiliary output: 5 Vdc, 0.1 amp
H3
Auxiliary output: 12 Vdc, 0.1 amp
H4
Auxiliary output: 13.8 Vdc, 0.1 amp
H5
Auxiliary output: 15 Vdc, 0.1 amp
H6
Auxiliary output: -5 Vdc, 0.1 amp
H7
Auxiliary output: -12 Vdc, 0.1 amp
H8
Auxiliary output: -15 Vdc, 0.1 amp
Output Redundancy Options
J2
N+1 Redundancy (Available on Single Output models only.) Allows up to 4 like models to be wired in N+1 redundancy. An internal isolation OR-ing diode is included in each power supply. This option forces equal current sharing among like model supplies. The DC output load lines and remote sense lines may be directly connected in parallel and all 'S bus' terminals must be connected together. The output voltage of each supply is individually set so that the difference between the highest and the lowest is less than 100 mv. The current limiting set point of each supply should be set at equal value. Power supply output current must be derated by 10%. Includes:
Voltage and current monitoring (Option C7).
Output blocking protection diode (Option E1).
$110.00
J3
'OR-ing' or 'Blocking Diode' Redundancy Redundancy is attained by simply wiring two units in parallel. Derate output by 10%. (Available on Single Output models only. Not available with options C9, E5.) Includes:
Non-latching OVP set 15% above rated output (Option A2).
Alarm with relay contacts that close when output voltage drops more than 10% below nominal (Option G1).
Output blocking protection diode (Option E1).
Remote sensing.
$210.00
Final Test Data
$35.00
K6
Final test data also includes an extended 8 hour burn-in.
Digital Voltage and Current Meters
$150.00
M3
Voltmeter accuracy is 0.5% ±1 LSB; current meter accuracy is 1% ±1 LSB.
Resistive Programming
$110.00
R1
Output voltage and current may be programmed from 0 to rated output. Programming: ohms per volt out = 10k÷VRated ±5%. Program resistors are connected from 'V pgrm' to '–Sense' and 'I pgrm' to '–Rtn'. (Not available with options C1, C2, C5, C6, G1,G2, G5,J3.)